1.
Rev. bras. eng. biomed ; 25(3): 145-152, dez. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-576299

ABSTRACT

Neste trabalho descrevemos um sistema on-line, chamado “Dose Fetal Web”, que calcula a dose fetal e os riscos radiológicos devido a exposições clínicas ou ocupacionais de gestantes. O sistema utiliza a metodologia matemática onde são usados coeficientes de conversão de dose uterina para dose fetal, gerados por meio de simulações pelo método de Monte Carlo. Para exposição médica de uma paciente gestante, uma base de dados de informações de operação de equipamentos acompanhados por um programa de garantia de qualidade e parâmetros fetais e maternos coletados durante exames de ultrassonografia obstétrica são incorporados na estimativa da dose fetal. No caso de dose fetal de uma trabalhadora gestante sujeita à exposição ocupacional (IOE),informações de uma base de dados de monitoração pessoal como dose ocupacional e carga de trabalho são usadas nos cálculos. No primeiro caso, considerando-se uma paciente gestante de 26 semanas submetida a um procedimento abdominal AP (tensão aplicada ao tubo de 70 kVp e filtração total de 3 mmAl), a dose fetal calculada pelo sistema foi 4,61 mGy e os riscos radiológicos obtidos foram 5,0·10-4 e 0,14 para a probabilidade de indução de retardamento mental e declínio de pontos de QI, respectivamente. No segundo caso, considerando-se uma IOE gestante, e assumindo-se que ela utilize um avental de proteção de 0,5 mm de equivalência em chumbo durante cada procedimento de radiologia intervencionista, e que a leitura pessoal de um dosímetro TLD portado fora do avental foi de 2 mGy/mês, a dose fetal calculada pelo sistema foi 0,02 mSv/mês.


In this paper we describe an online software, named “Dose Fetal Web”, which calculates the dose of the fetus and the radiological risks from both medical and occupational exposures of pregnant women. The software uses a mathematical methodology where coefficients for converting uterus to fetal dose, NUD, have been calculated by using Monte Carlo simulation. In the fetal dose from diagnostic medical examination of the pregnant patient, database information regarding output and other equipment related parameters from the QA database, maternal and fetal parameters collected by ultrasound procedures were used for the fetal dose estimation. In the case of fetal dose of the pregnant staff member the database information regarding routine individual monitoring dosimetry, such as occupational dose and workload, were used for the estimation. In the first case, suppose a 26 weeks pregnant patient had to undergo a single AP Abdomen procedure (70 kVp peak tube voltage and total filtration 3 mmAl), the fetal dose calculated by the software was 4.61 mGy and the radiological risks would be 5.0·10-4 and 0.14 to the probability of mental retardation induction and decline in the IQ score, respectively. In the second case,considering that the staff member can be pregnant, and assuming that she wore a 0.5 mm lead equivalent apron during every interventional radiology procedure and a personal dosimetry reading of 2 mGyTLD/month measured with the TLDs outside the apron, the fetal dose calculated by the software was 0.02 mSv/month.


Subject(s)
Humans , Female , Pregnancy , Radiotherapy Dosage/standards , Fetus/radiation effects , Pregnancy/radiation effects , Radiation Protection/instrumentation , Radiotherapy, Computer-Assisted/instrumentation , Radiotherapy, Computer-Assisted/standards , Radiotherapy, Computer-Assisted , Maternal-Fetal Exchange/radiation effects , Calibration/standards , Maternal Exposure/adverse effects , Maternal Exposure/prevention & control , Internet/trends , Internet , Occupational Risks , Radiation Exposure Measurement
2.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.413-414, tab, graf.
Monography in Portuguese | LILACS | ID: lil-236420

ABSTRACT

Considerando-se que devido a exigência legais, todos os instrumentos utilizados para medidas em radiologia diagnóstica devem ser submetidos à calibração, foram testados alguns monitores portáteis (do tipo câmaras de ionização) que normalmente são utilizados para levantamento radiométrico utilizando-se as qualidades estabelecidas de acordo com a norma alemã DIN6872, de 30 a 50 kV, no sistema de radiação X de energias baixas utilizado a nível terapia.


Taking into account the Brazilian law requirements that ali dosemeters used in diagnostic radiology measurements must be calibrated, portable instruments (ionization chambers type) were tested in the established diagnostic radiology qualities of the German Norm DIN 6872, from 30 to 50 kV, of a therapy levei low energy Xray system.


Subject(s)
Radiology , Radiotherapy, Computer-Assisted/standards , Calibration/standards , Equipment and Supplies/standards , Radiation Protection/methods